1
00:00:01,010 --> 00:00:02,490
Let's do some testing.

2
00:00:04,920 --> 00:00:12,210
One writer one interface cereal 0 1 0 encapsulation.

3
00:00:12,550 --> 00:00:16,270
I've said this to me before I do that.

4
00:00:16,270 --> 00:00:20,000
Notice there are various options and I'll say this too.

5
00:00:20,590 --> 00:00:28,390
And what we should see is that the interface goes down and there you go line protocol these don't show

6
00:00:28,540 --> 00:00:35,140
interface serial 0 1 0 0.

7
00:00:35,270 --> 00:00:39,540
What you'll notice is the physical interfaces up but the line protocol is down.

8
00:00:39,770 --> 00:00:49,600
So there's a problem at the layer to this interface is using PDP where as router to show interface serials

9
00:00:49,600 --> 00:00:53,390
0 1 0.

10
00:00:53,410 --> 00:01:00,910
So what is routed to using as we can see here ratus using HDL see the physical interface is still up

11
00:01:01,280 --> 00:01:06,300
to the line protocol is down because different solutions are being used.

12
00:01:06,310 --> 00:01:16,430
The one side is using the other side is using HTL see physical clock rate is there but the line protocols

13
00:01:16,430 --> 00:01:17,060
are down.

14
00:01:17,310 --> 00:01:21,280
So on the site I'll change the encapsulation

15
00:01:24,180 --> 00:01:32,820
to BP and hopefully we should see the interfaces come up and they you go into faces come up and on the

16
00:01:32,820 --> 00:01:34,510
side interfaces come up.

17
00:01:34,590 --> 00:01:42,960
What I'd like you to see is that different encapsulations can be used on interfaces on a router but

18
00:01:42,990 --> 00:01:44,870
across a point to point link.

19
00:01:44,880 --> 00:01:48,080
Both sides have to agree on encapsulation.

20
00:01:48,300 --> 00:02:05,860
So as an example on this 1841 router Sariel 0 1 0 is using PDP but on this interface serial 0 0 0 encapsulation

21
00:02:05,860 --> 00:02:07,170
is HDL C..

22
00:02:07,360 --> 00:02:15,730
That means that this cable is using HDL C and this cable is using GPP the 1841 rodded to device needs

23
00:02:15,730 --> 00:02:20,930
to be using PDP and the 17:21 needs to be using HDL.

24
00:02:21,160 --> 00:02:26,270
So the same encapsulation has to be used on both ends.

25
00:02:26,300 --> 00:02:31,760
If I shut down an interface I'm going to shut down.

26
00:02:31,780 --> 00:02:34,370
Serial is 0 1 0.

27
00:02:35,830 --> 00:02:43,370
Notice on this side we see that the interface went down and the line protocol went down.

28
00:02:44,470 --> 00:02:48,590
Show interface serial is 0 1 0.

29
00:02:51,370 --> 00:02:55,920
Here the physical interface has gone down as well as the line protocol.

30
00:02:56,050 --> 00:03:02,640
If there's a problem between the DTV and the DC we are going to see the physical interface go down shut

31
00:03:02,700 --> 00:03:04,830
it on the side.

32
00:03:05,560 --> 00:03:11,760
You should see the interface come up in the same way if I shut it down on this side

33
00:03:16,300 --> 00:03:23,050
we'll see the interface go down on Rotto one and there you go into face went down the line protocol

34
00:03:23,050 --> 00:03:29,200
and don't shut it.

35
00:03:29,300 --> 00:03:31,850
It may take a few seconds and that's because

36
00:03:34,560 --> 00:03:38,030
the keep alive the same every ten seconds on a link.

37
00:03:38,250 --> 00:03:40,640
So it may not be instant.

38
00:03:40,660 --> 00:03:44,130
Here it is because this cable is connected back to back.

39
00:03:44,230 --> 00:03:50,240
But in the real world that may not be true may take a while for the interface to go down to come up.

40
00:03:51,960 --> 00:03:54,390
So what do you need to remember.

41
00:03:54,480 --> 00:04:01,560
It's fairly easy to configure serial interfaces on the one interface.

42
00:04:01,560 --> 00:04:06,730
We changed the encapsulation but on the other we didn't.

43
00:04:06,960 --> 00:04:14,360
So all we need to do is no shut the interface and put an IP address on and configure the relevant bandwidth.

44
00:04:14,730 --> 00:04:21,620
If it is a DC interface like in this example we need to put the clock rate on.

45
00:04:21,840 --> 00:04:31,250
So on DC interfaces you put the clock rate but not on DTV interfaces on a DTV you put the bandwidth

46
00:04:31,560 --> 00:04:35,850
and the relevant encapsulation HPLC once again is the default.
